  Datasheet File OCR Text:
  gas discharge tubes RL600Q-3012 series speci?cations are subject to change without notice. please refer to http://www.ruilon.com for current information. electronic s circuit prote ct io n system
page:1 speci?cations are subject to change without notice. please refer to http://www.ruilon.com for current information. gas discharge tubes - RL600Q-3012 series 1. very small size 2. suitable for direct strikes 3. very fast response time 4. stable performance over life 5. high insulation resistance 6. rohs compatible features recommended applications 1. ac power lines n-pe applications 2. class i requirements gdt introduction:gas discharge tubes (gdt) use noble gasses enclosed in ceramic tubes to provide an alternate circuit path for voltage spikes.the ceramic envelope and with nickel connectors allow for high load s and ruilon offers products that function at 20ka,40ka,50ka,60ka,100ka&150ka. the breakdown voltages of the devices have a wide range (up to 20% tolerance).major applications are high frequency telecommunication lines,stations, security systems,hid and high quality surge protection devices (spd). electrical specifcations series/type: RL600Q-3012 3012a 3012b 3012c dc spark-over voltage 1) 2) > 600 > 600 > 600 v front of wave spark-over voltage at 1.2/50 s, 6 kv < 1500 < 1500 < 1500 v breakdown time typical value < 100 < 20 < 50 < 100 < 20 ns ns insulation resistance at 100 vdc > 1 > 1 > 1 g class i according to en 61643-11 max.continuous operating voltage at 50/60 hz uc nominal discharge current 8/20 s in impulse current 10/350 s iimp follow current at 50/60 hz if 255 150 50 100 264 50 50 100 255 50 50 100 v ka ka a ac discharge current (tov 3)) 1 operation 50 hz, 0.2 s 300 300 300 a weight ~ 35 ~ 35 ~ 100 g operation and storage temperature -40 ... +90 -40 ... +90 -40 ... +90 c climatic category (iec 60068-1) 40/ 90/ 21 40/ 90/ 21 40/ 90/ 21 40/ 90/ 21 1. at delivery aql 0.65 level ii, din iso 2859 2. in darkness w/o storage 3. tov C temporary over voltage circuit prote ct io n system
gas discharge tubes - RL600Q-3012 series page:2 speci?cations are subject to change without notice. please refer to http://www.ruilon.com for current information. rl600g-3012a series dimension unit:mm ordering code and packing advice rl600g-3012= 20 pcs. on trays circuit prote ct io n system
page:3 speci?cations are subject to change without notice. please refer to http://www.ruilon.com for current information. gas discharge tubes - RL600Q-3012 series rl600g-3012b series dimension unit:mm circuit prote ct io n system
gas discharge tubes - RL600Q-3012 series page:4 speci?cations are subject to change without notice. please refer to http://www.ruilon.com for current information. storage conditions: 1. storage temperature: -10c~+40c 2. relative humidity:75%rh 3. keep away from corrosive atmosphere and sunlight. period of storage: 1 year warehouse storage conditions of products rl600g-3012c series dimension unit:mm circuit prote ct io n system
page:5 speci?cations are subject to change without notice. please refer to http://www.ruilon.com for current information. ruilongyuan electronics co., ltd. reproducing and modifying information of the document is prohibited without permission from ruilongyuan international inc. ruilongyuan international inc. reserves the rights to make changes of the content herein the document anytime without noti?cation. please refer to our website for the latest document. ruilongyuan international inc. disclaims any and all liability arising out of the application or use of any product including damages incidentally and consequentially occurred. ruilongyuan international inc. does not assume any and all implied warranties, including warranties of ?tness for particular purpose, non-infringement and merchantability. applications shown on the herein document are examples of standard use and operation. customers are responsible in comprehending the suitable use in particular applications.ruilongyuan international inc. makes no representation or warranty that such applications will be suitable for the specifed use without further testing or modifcation. the products shown herein are not designed and authorized for equipments requiring high level of reliability or relating to human life and for any applications concerning life-saving or life-sustaining, such as medical instruments, transportation equipment,aerospace machinery et cetera. customers using or selling these products for use in such applications do so at their own risk and agree to fullyindemnify ruilongyuan international inc. for any damages resulting from such improper use or sale. tel: +86-755-8290 8296 fax: +86-755-8290 8002 e-mail: jack@ruilon.com circuit prote ct io n system


▲Up To Search▲   

 
Price & Availability of RL600Q-3012

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X